Indoor MV Metal-clad Digital Switchgear

Indoor MV Metal-clad Digital Switchgear is a complete set of power distribution equipment for 3.6~12KV three-phase AC 50Hz/60Hz single busbar and single busbar segmentation system. Mainly used in power stations, small and medium-sized generators, industrial and mining enterprises and institutions power distribution, residential district power distribution, as well as electrical industry system of the secondary substation receiving power, power transmission and large high-voltage motor starting.For control, protection and monitoring. The switchgear meets the requirements of DL/T404, IEC298, GB3906 and other standards,and has the function of "five-prevention" interlock.

Products Details

Use conditions

★Ambient air temperature; maximum temperature +40℃, minimum temperature -15℃. Average daily temperature not exceeding 35℃. ★Humidity conditions: daily average relative humidity: ≤95%. Daily average water vapor pressure doesn’t exceed 2.2kPa; monthly average relative humidity: ≤ 90%, monthly average water vapor pressure does not exceed 1.8kPa. ★Altitude: 3000m and below. ★Earthquake intensity: no more than 8 degrees. ★No fire and explosion hazards; serious pollution, chemical corrosion and violent vibration of the place.

Main features

★High protection level of equipment shell, IP4X protection level, IP2X protection level when the breaker room door is fully open; enhanced security, reliability and accuracy. ★Conform to the " five prevention" requirements, and the same functional units can be interchangeable. ★Configuration of trolley type vacuum circuit breaker, complete protection function, convenient maintenance and repair. ★The equipment shell is made of zinc coated steel plate, with high mechanical strength, impact resistance and corrosion resistance. ★Reduce the impact on the environment. ★Non-ferromagnetic resonance solution without traditional PT.

Order instructions

★Power supply system characteristics: rated voltage, current, frequency. ★plan layout diagrams, primary system diagrams, secondary schematic diagrams. ★Operating conditions: maximum and minimum air temperature, moisture difference, humidity, altitude and pollution level, other external factors affecting the operation of the equipment. ★special conditions of use, should be described in detail. ★Please attach a detailed description for other special requirements.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours