Low-Voltage Fixed Separate Switchgears

Low-voltage Fixed Separate Switchgear is suitable for low-voltage power distribution systems with AC 50HZ/60HZ, rated working voltage 380~660V and below, for power receiving, power feeding, bus linkage, motor control and power compensation.It covers the functions of power center (PC) and motor control center (MCC).It is widely used in electric power, airports, ports, subways, mines, metallurgy, textiles, chemicals, residential quarters, high-rise buildings and other places. Products meet the requirements of IEC, GB7251 and other standards.

Products Details

Use conditions

Maximum and minimum air temperatures are +40°C and -5°C, respectively. Maximum daily average temperature is 35 °C. At a maximum temperature of +40°C, the relative humidity of the air is less than 50%. At lower temperatures, a higher relative humidity is permitted, such as 90% at +20°C, and should take into account the potential for sporadic condensation due to temperature variations. "Indoor installation and use, it's use site's altitude shall not exceed 2000 meters." The vertical surface and the installation of the equipment are not inclined more than 5%. No more than 8 degrees of earthquake intensity. There are no major pollution issues, chemical corrosion issues, fire and explosion risks, or ominous vibrations in the area.

Main features

High protection level of equipment shell, reaching IP42. The main incoming line and main outgoing line of each functional unit are fixedly connected to improve the reliability of power supply; For the safety of people who use the equipment and to prevent electrical faults from spreading, each functional unit is designated a separate compartment. The cabinet frame is assembled by C-shaped steel bolts, and the compartment size are changed by patterned 25mm, with a high degree of standardization. Low maintenance cost Reliable, flexible and expandable design, saving floor space.

Order instructions

★ Power supply system characteristics: rated voltage, current, frequency. ★ Plan layout diagrams, primary system diagrams, secondary schematic diagrams. ★ Operating conditions: maximum and minimum air temperature, moisture difference, humidity, altitude and pollution level, other external factors affecting the operation of the equipment. ★ special conditions of use, should be described in detail. ★ Other special requirements.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours